Sizing a biofilter: what the numbers actually depend on
Biofilter sizing does not start with choosing the media the bacteria grow on. It starts with the daily ammonia load, divided by the rate at which each square metre of media surface removes ammonia. That rate is not fixed: temperature, target ammonia concentration, dissolved oxygen and the organic carbon reaching the media can move it by a factor of five before a single piece of media has been bought.

Key takeaways
- Biofilter size starts with the feed going in each day, not with the filter material on offer.
- The same material works faster or slower depending on water temperature, oxygen supply and how clean the water must be kept.
- Figures from cold-water farms cannot simply be copied to warm-water farms. Unadjusted, they leave the filter badly mis-sized.
- Material with more surface area packed in makes a filter more compact, but each part of that surface does not work harder.
- Waste solids reaching the filter feed the wrong bacteria and can quietly take a large share of its capacity. Good solids removal upstream protects it.
- Asking for cleaner water means a larger filter. Decide on purpose, not by default.
What this means for design
A biofilter is the part of a recirculating system where bacteria convert the ammonia that fish excrete into a far less harmful form. Its size matters to anyone building or running a farm, because a filter that is too small cannot keep ammonia down when the farm is fully stocked, and one that is too large ties up money and floor space. The size a farm needs depends less on the filter material than on the conditions the filter works under, so the steps below are about pinning those conditions down before a volume is chosen.
Start by writing down how fast the filter is assumed to work, together with the conditions that figure was measured under. Designers call this figure the areal removal rate: the grams of ammonia nitrogen that each square metre of biofilm, the layer of bacteria coating the filter material (the media), removes in a day. It belongs beside the feed rate and the excreted fraction (the assumed share of the nitrogen in the feed that ends up as ammonia in the water), where a reviewer can see it. Any published rate should be corrected for temperature before it is used, because the same bacteria work at a different pace in warm water and in cold, and the correction factor (the temperature coefficient) should be stated. Left uncorrected, the cold-water rate in the worked example below sizes a warm-water barramundi reactor at 173 m³ rather than 34 m³.
Decide on purpose how low the ammonia concentration in the water is to be held, a target usually expressed as total ammonia nitrogen (TAN). Cleaner water means a larger filter: it costs about 62 per cent more media area to halve the target TAN concentration.
Then size the solids removal, the equipment that takes waste particles out of the water before they reach the filter, as though the biofilter depended on it. It does: waste solids carry organic carbon, which feeds competing bacteria, and once the ratio of organic carbon to TAN in the water reaching the media (the C/N ratio) is 1 or above, the removal rate falls by about half. If the reactor is a packed bed, in which the media sit still, rather than a moving bed, in which the media are kept in motion, treat that dependence as tighter still.
Two habits are worth building in. The first is to allow for biofilm history, meaning the conditions the bacteria have grown under: carriers (the individual pieces of media) grown at a low TAN concentration showed less than half the fitted rate constant of carriers grown at a high one. The rate constant here is the empirical constant in the rate equation, so this describes observed removal performance, not a fixed property of the bacteria. A plant commissioned gently can under-perform its design rate for months. The second is to keep alkalinity dosing in the design from the start. Alkalinity is the water's capacity to neutralise acid, and the dosing is there for pH stability rather than for rate.
The rest of this article sets out the evidence behind each of these steps.
Biofilter sizing starts with four numbers, not a volume
Biofilter sizing for a recirculating aquaculture system (RAS), a farm that cleans and reuses its water, is a chain of four numbers, and the volume of filter material comes last. Ask how big the biofilter should be and the answer usually arrives as a media volume. That is the last number in the chain, not the first. The chain runs from feed on the design day, to the TAN produced, which at steady state is the removal the filter has to achieve, to the areal rate the media can deliver under the farm's conditions, and only then to media area and reactor volume. The first article in this series, on why every aquaculture design starts with a mass balance, worked the front half, turning feed rate, feed conversion and diet composition into a daily TAN load and the nitrification stoichiometry that follows from it (Ebeling et al., 2006). Nitrification is the bacterial conversion of ammonia to nitrate. This article takes the back half, where kilograms per day become square metres of biofilm.
That step needs an areal removal rate, in grams of ammonia nitrogen per square metre of biofilm surface per day. A rate quoted without its conditions is not a design number. Rusten and colleagues set out what moves it in a moving bed reactor, a tank in which small plastic carriers coated in biofilm are kept in motion: the organic load, the reactor dissolved oxygen (DO) concentration, the TAN concentration, temperature, pH and alkalinity, and the previous history of the biofilm (Rusten et al., 2006). Five of those six are decisions made about the farm, not about the plastic.
Key figures
The table below collects the handful of figures that govern the design, each with the conditions it applies under. The sections that follow explain them.
| Figure | Conditions | Source |
|---|---|---|
| Temperature coefficient of 1.09 per °C | Moving bed reactors; acts on the reaction rate constant | Rusten et al. (2006) |
| Rate proportional to TAN concentration raised to the power 0.7 | Moving bed reactors; halving the target TAN costs about 38 per cent of the rate and adds 62 per cent to the media area | Rusten et al. (2006) |
| Dissolved oxygen to TAN ratio of about 3.2 | The transition from oxygen limitation to ammonia limitation, absent biodegradable organic matter | Rusten et al. (2006), citing Szwerinski et al. (1986) |
| TAN removal 30 per cent lower at C/N 0.5, 45 per cent down at C/N 1 and about 52 per cent at C/N 2 | Compared with C/N 0; pilot submerged biofilters on seawater at 20 ± 1 °C, pH 7.5 to 8.0, influent TAN held at 2 mg/L | Michaud et al. (2006) |
| Nitrification rate halved | Moving carriers from pH 7.3 and 2.3 mmol/L alkalinity to pH 6.7 and 1.1 to 1.2 mmol/L, at 15.6 to 16.2 °C with DO of 6.3 to 6.8 mg/L | Rusten et al. (2006) |
| 300 m²/m³ of reactor volume | Specific surface area of Kaldnes K1 at 60 per cent fill | Rusten et al. (2006) |
Areal or volumetric: the same media, two different answers
A biofilter's performance can be counted two ways: per square metre of media surface (the areal rate) or per cubic metre of media (the volumetric rate). The two can rank the same media in opposite orders, so a rate means little until its basis is stated. Media are sold on specific surface area, the square metres of surface packed into each cubic metre of media, so it is tempting to treat area as a proxy for performance. It is not, and the cleanest demonstration runs three media side by side. Harwanto et al. (2011) loaded a fluidised sand filter (7,836 m²/m³), a trickled polystyrene microbead filter (3,287 m²/m³) and a trickled Kaldnes bead filter (500 m²/m³) at 5, 25 and 50 g TAN/m³/day in fresh water at 22.4 to 25.6 °C, with dissolved oxygen of 6.7 to 9.1 mg/L and pH 6.7 to 7.4. In a fluidised sand filter, water flowing upward keeps a bed of sand grains suspended; in a trickling filter, water runs down over media standing in air. At the highest loading the volumetric rates were close: 323, 311 and 288 g TAN/m³/day respectively, a spread of 12 per cent across media whose surface areas differ by a factor of nearly sixteen.
Convert to an areal basis and the order inverts. Per square metre of media surface, the Kaldnes beads removed 0.58 g TAN/m²/day, the microbeads 0.095 and the sand 0.041, a fourteen-fold spread running the other way. Neither ranking is wrong. High specific surface area buys compactness, and each square metre works less hard, because biofilm on a densely packed medium sits in a poorer oxygen and substrate environment. Which number matters depends on what is scarce: floor space, or confidence that the filter will hold ammonia down when loaded hard.
The table below sets published removal rates beside the conditions each was measured at.
| Reactor and media | Rate reported | Conditions it was measured at |
|---|---|---|
| Kaldnes K1 moving bed, fresh water, brown trout and Arctic char | 0.30 g N/m²/day | 9 °C, DO 9.7 mg/L, pH 6.2, TAN load 0.45 g/m²/day (Rusten et al., 2006) |
| Kaldnes K1 moving bed, marine turbot RAS, in service | 0.25 g N/m²/day | full-scale rate at the time carriers were sampled, salinity 21 to 24, reactor about 2 years old (Rusten et al., 2006) |
| The same turbot carriers, bench test with ammonium in excess | 0.95 g N/m²/day | rate corrected to 15 °C, salinity 21, pH 7.6, DO 6.9 mg/L (Rusten et al., 2006) |
| Nitrifying trickling filter, laboratory, ammonia dosed, best of 45 combinations | 0.241 g N/m²/day | 27 °C, hydraulic loading 11 m³/m²/h, TAN load 9 g/m³/day (Godoy-Olmos et al., 2019) |
| Kaldnes beads, trickled, 500 m²/m³ | 288 g/m³/day, or 0.58 g/m²/day | 22.4 to 25.6 °C, DO 6.7 to 9.1 mg/L, pH 6.7 to 7.4, load 50 g/m³/day, steady TAN 0.9 mg/L (Harwanto et al., 2011) |
| Polystyrene microbeads, trickled, 3,287 m²/m³ | 311 g/m³/day, or 0.095 g/m²/day | as above, steady TAN 0.5 mg/L (Harwanto et al., 2011) |
| Fluidised sand, 7,836 m²/m³ | 323 g/m³/day, or 0.041 g/m²/day | as above, steady TAN 0.5 mg/L (Harwanto et al., 2011) |
| Local and commercial biomedia, pilot RAS | 599 ± 15.8 (coconut shell) down to 343 ± 8.9 (cattle horn) g TAN/m³/day | 1 m³ pilot RAS, Nile tilapia, dosed ammonium chloride; the paper's reported highest and lowest (Mnyoro et al., 2022) |
A moving bed belongs on the volumetric axis too, because reactor volume is what a buyer actually pays for. Kaldnes K1 at 60 per cent fill offers 300 m²/m³ of reactor volume (Rusten et al., 2006), so a bed running at 0.30 g N/m²/day delivers about 90 g N/m³/day. That rate was measured at 9 °C, while the fluidised sand reached 323 g/m³/day at 22.4 to 25.6 °C. Corrected to 24 °C at 1.09 per °C, the K1 rate becomes about 1.1 g N/m²/day, or roughly 330 g N/m³/day, level with the sand. The correction carries the same extrapolation caution as the worked example below, and Harwanto's was a small freshwater trial loaded hard, not a commercial comparison. Together they show why a rate means little until its basis and temperature are stated; they do not settle which equipment to buy.
Two entries deserve attention. The bench figure of 0.95 g N/m²/day measures potential, not duty. Carriers from a Spanish farm managed 0.07 g N/m²/day against 0.95 for carriers from a Portuguese farm. Two causes run together in that gap. The Spanish reactor had been operating four months against about two years, and its carriers had seen TAN at or below 0.1 mg/L against 0.4 to 0.6 mg/L (Rusten et al., 2006). Fluidised sand, meanwhile, earns its place on removal efficiency rather than areal rate: in an end-of-pipe trial treating dilute farm effluent rather than recirculating loop water, full-scale units managed by biofilm shearing removed 86 to 88 per cent of inlet TAN each pass (Davidson et al., 2008), which is why it is favoured where ammonia and nitrite must stay consistently low (Summerfelt, 2006).
Temperature, ammonia and oxygen set the rate
A biofilter removes ammonia faster in warmer water and more slowly when the ammonia concentration is held low, and it is limited by oxygen only when ammonia is plentiful. Three relationships do most of the work, with pH and alkalinity a fourth.
Temperature acts on the reaction rate constant, the measure of how fast the biofilm works, through an Arrhenius-type coefficient: a multiplier applied once for each degree of temperature change, so that its effect compounds. For moving bed reactors that coefficient is 1.09 per °C (Rusten et al., 2006). Between a Norwegian smolt house at 12.5 °C and a tropical barramundi (Lates calcarifer) system at 28 °C that is a factor of 3.8, on the same media with the same biofilm. A cold-water salmonid rate applied unadjusted to a warm-water farm is wrong by roughly that margin.
Ammonia concentration acts through a fractional-order relationship, rate proportional to TAN concentration raised to the power 0.7 (Rusten et al., 2006). In plain terms, the rate falls as the water is kept cleaner, though by less than in proportion. Halving the target TAN costs about 38 per cent of the rate and adds 62 per cent to the media area. This is where a water-quality target quietly becomes a capital cost.
Oxygen decides which substrate is limiting, that is, whether the bacteria run short of oxygen or of ammonia first. Absent biodegradable organic matter, the transition from oxygen limitation to ammonia limitation sits at a dissolved oxygen to TAN ratio of about 3.2 (Rusten et al., 2006, citing Szwerinski et al., 1986). Because farm TAN normally runs below 1 mg NH₄-N/L, ammonia is usually limiting. That is why a well-aerated biofilter cannot be pushed harder simply by aerating it more. The exception is a reactor running at low DO or under a heavy organic load, where oxygen becomes limiting and more aeration does help. At 15 °C and low organic load the crossover moves from a TAN of about 0.5 mg/L at a reactor DO of 2 mg/L to about 1.7 mg/L at 6 mg/L.
pH and alkalinity are the fourth term. Moving carriers from pH 7.3 and 2.3 mmol/L alkalinity to pH 6.7 and 1.1 to 1.2 mmol/L halved the nitrification rate at 15.6 to 16.2 °C with DO of 6.3 to 6.8 mg/L (Rusten et al., 2006). Alkalinity is a separate question from rate, and worth not conflating: in a semi-commercial Atlantic salmon (Salmo salar) smolt RAS at 12.5 °C, the areal nitrification rate was actually highest at the lowest alkalinity, yet a nominal 10 mg/L as CaCO₃ still raised steady-state TAN compared with 70 or 200 mg/L, and the case for holding 70 mg/L rests on pH stability and on having time to react to a dosing failure rather than on the rate (Summerfelt et al., 2015).
Organic carbon is the term that quietly halves the filter
The dominant argument for solids removal upstream is not sludge handling. It is that particulate organic carbon arriving at the media takes the filter's rate away. Waste solids feed heterotrophs, bacteria that live on organic carbon rather than ammonia, and these compete with the nitrifying bacteria for oxygen and space.
Michaud et al. (2006) ran four pilot submerged biofilters on seawater at 20 ± 1 °C, pH 7.5 to 8.0, influent TAN held at 2 mg/L, dosed with particulate organic matter from a sea bass RAS particle separator at C/N ratios of 0, 0.5, 1 and 2, C/N being the ratio of organic carbon dosed to the TAN supplied to the filter, not a carbon to nitrogen ratio measured elsewhere in the system. TAN removal was 30 per cent lower at C/N 0.5 than at C/N 0, and about half was gone at the higher ratios: 45 per cent down at C/N 1, about 52 per cent at C/N 2. The biofilm did not simply thin out; its make-up shifted toward heterotrophs. Total attached cells roughly doubled, from 1.8 × 10⁷ to 3.9 × 10⁷ per gram of media, while cultivable heterotrophs rose 88-fold, to 4.4 × 10⁶ CFU/g. Half the filter, gone, with nothing visibly wrong.
The mechanism is competition for oxygen and space in the outer biofilm rather than direct toxicity, so it shows up in the oxygen budget too. Organic load is expressed here as BOD₅, the five-day biochemical oxygen demand, a measure of the oxygen the organic matter will consume. In a moving bed reactor, heterotrophic activity in the outer layer costs an estimated 0.5 mg O₂/L at very low organic loads, rising to about 2.5 mg O₂/L at 1.5 g BOD₅/m²/day. The matching rate figures were measured with TAN in excess, above 2.5 mg N/L, so they are an upper bound rather than a farm condition: achieving 1 g NH₄-N/m²/day at 15 °C needed a reactor DO of about 5 mg/L at an organic load of 1 g BOD₅/m²/day, and about 8 mg/L at 3 g BOD₅/m²/day (Rusten et al., 2006). They show the shape of the penalty, not an aeration specification.
Reactor type changes how much of this you absorb. On seawater at 20 ± 2 °C, ammonium oxidation in one hour in a static mineral bed fell from 95 per cent at C/N 0 to 77.2 ± 2 per cent across C/N 0.5 to 2, and to 48.9 per cent at C/N 4, while a moving plastic bed held 77.6 ± 4 per cent from C/N 0 through 2 (Michaud et al., 2014). A packed bed pays for upstream solids failures more heavily than a moving bed does, the difference credited to self-cleaning. The fix behaves as expected: ultrafiltration (filtration through a fine membrane) of 10 to 15 per cent of the flow in a pilot Atlantic salmon RAS gave lower turbidity, lower particulate organic carbon and slightly lower TAN than the conventional system beside it (Fossmark et al., 2020).

The biofilter sizing chain. Feed sets the ammonia load, but the areal removal rate in step three is where temperature, target ammonia concentration and organic loading decide how much media the same duty needs. Original diagram, AquaBlueprint.
A worked example: the biofilter for a 100 t/year barramundi RAS
The same farm, with the same fish, feed and media, can need anything from 34 m³ to 173 m³ of reactor volume depending on the removal rate assumed. The arithmetic below shows why.
Take the nominal 100 t/year barramundi system from the first article. On the design day it takes 480 kg of a 45 per cent protein diet, carrying 480 × 0.45 × 0.16 = 34.56 kg of nitrogen (feed, multiplied by its protein fraction and by the nitrogen fraction of protein). At an excreted fraction of 0.45, the assumed share of that nitrogen that ends up as TAN, that is 15.55 kg of ammonia nitrogen per day, or 15,552 g/day the biofilter must remove at steady state, which is what the table divides by. Media area is that load divided by the areal rate; reactor volume is the area divided by specific surface area, taken here as 300 m²/m³ for Kaldnes K1 at 60 per cent fill (Rusten et al., 2006). Each row of the table applies a different rate assumption to that same load; θ (theta) is the temperature coefficient.
The 0.45 is a design assumption carried from the first article, not a biological constant. It moves with species, diet, feed waste and growth rate, and should be replaced with a measured figure once the farm is running. The widely used rule of thumb of 0.092 kg TAN per kg of protein fed works out to about 0.58 of feed nitrogen, which would raise the load, and every volume below, by about 28 per cent.
| Rate assumption | Areal rate (g N/m²/day) | Media area (m²) | K1 volume at 60% fill (m³) |
|---|---|---|---|
| Cold-water salmonid figure used unadjusted, 9 °C | 0.30 | 51,800 | 173 |
| Same figure corrected to 20 °C at θ = 1.09 | 0.77 | 20,100 | 67 |
| Corrected to 28 °C at θ = 1.09 | 1.54 | 10,100 | 34 |
| 28 °C, but organic carbon reaching the media at C/N ≥ 1 | 0.77 | 20,200 | 67 |
| 28 °C, clean water, target TAN halved (order 0.7) | 0.95 | 16,400 | 55 |
Five times the reactor volume separates the first row from the third, on the temperature assumption alone. The fourth row costs as much as an 8 °C drop in temperature, and it is won or lost entirely in the drum filter, the rotating screen that removes solids, upstream. The fifth is a water-quality decision most design briefs never price.
Three cautions. The volumes are steady-state figures for the average design-day load. They carry no allowance for the peak load after feeding, no safety factor, no redundancy and no start-up allowance for a biofilm that is still maturing, all of which a real design adds on top. The temperature correction extrapolates a coefficient fitted over a narrower range than 9 to 28 °C and assumes the same TAN concentration at both ends, so the warm-water rows show where the sensitivity lies rather than specify a reactor. And no peer-reviewed areal rate measured on a barramundi system surfaced in the search behind this article, a gap to close with a pilot rate test on the farm's own water.
In practice
AquaBlueprint is a web-based design platform for aquaculture systems that works through mass balance, component sizing and financial feasibility to produce a design report summary and a bill of materials. Its component sizing follows the logic set out in this article: it carries the daily TAN load through to media area and reactor volume with the temperature correction, the concentration order and the organic loading penalty left visible as editable assumptions. The methods implement widely accepted industry design standards, and the output is a design aid. It cannot replace a rate test on the farm's own water.
Sized properly, a biofilter is unremarkable. Sized from a media catalogue, it is the component most likely to be the reason a system cannot carry the biomass it was sold on.
Questions practitioners ask
How do I calculate biofilter size for a RAS?
Start with the daily ammonia load, which follows from the feed fed on the design day. Divide that load by the areal removal rate, the grams of ammonia nitrogen each square metre of biofilm removes in a day under the farm's own conditions, to get the media surface area. Then divide the area by the specific surface area of the media to get reactor volume. Kaldnes K1 at 60 per cent fill offers 300 m²/m³ (Rusten et al., 2006).
What nitrification rate should I assume for moving bed media?
No single rate applies. Published figures for Kaldnes K1 carriers run from 0.30 g N/m²/day in fresh water at 9 °C to 0.95 g N/m²/day in a bench test with ammonium in excess, corrected to 15 °C (Rusten et al., 2006). The bench figure is a potential, not a design duty: the same carriers ran at 0.25 g N/m²/day in service. Take a published rate, correct it for the farm's temperature and target ammonia concentration, and record it as an assumption with its conditions attached. A pilot rate test on the farm's own water closes the gap.
How much does temperature change biofilter size?
Considerably. For moving bed reactors the temperature coefficient is 1.09 per °C (Rusten et al., 2006), a factor of 3.8 between 12.5 °C and 28 °C. In the worked example, the same barramundi farm needs 173 m³ of reactor volume when a cold-water rate is used unadjusted and 34 m³ once that rate is corrected to 28 °C. The correction extrapolates the coefficient beyond the range it was fitted over, so it shows sensitivity rather than a specification.
Why do solids reduce biofilter performance?
Waste solids carry organic carbon, which feeds heterotrophs, bacteria that compete with the ammonia-removing bacteria for oxygen and space in the biofilm. In pilot biofilters, TAN removal was 30 per cent lower at a C/N ratio of 0.5 than at C/N 0, and about half was gone at ratios of 1 and 2 (Michaud et al., 2006). Good solids removal upstream protects the filter's capacity.
References
Davidson, J., Helwig, N. and Summerfelt, S.T. (2008). Fluidized sand biofilters used to remove ammonia, biochemical oxygen demand, total coliform bacteria, and suspended solids from an intensive aquaculture effluent. Aquacultural Engineering 39, 6-15. https://doi.org/10.1016/j.aquaeng.2008.04.002
Ebeling, J.M., Timmons, M.B. and Bisogni, J.J. (2006). Engineering analysis of the stoichiometry of photoautotrophic, autotrophic, and heterotrophic removal of ammonia-nitrogen in aquaculture systems. Aquaculture 257, 346-358. https://doi.org/10.1016/j.aquaculture.2006.03.019
Fossmark, R.O., Vadstein, O., Rosten, T.W., Bakke, I., Košeto, D., Bugten, A.V., Helberg, G.A., Nesje, J., Jørgensen, N.O.G., Raspati, G., Azrague, K., Østerhus, S.W. and Attramadal, K.J.K. (2020). Effects of reduced organic matter loading through membrane filtration on the microbial community dynamics in recirculating aquaculture systems (RAS) with Atlantic salmon parr (Salmo salar). Aquaculture 524, 735268. https://doi.org/10.1016/j.aquaculture.2020.735268
Godoy-Olmos, S., Martínez-Llorens, S., Tomás-Vidal, A., Monge-Ortiz, R., Estruch, G. and Jover-Cerdá, M. (2019). Influence of temperature, ammonia load and hydraulic loading on the performance of nitrifying trickling filters for recirculating aquaculture systems. Journal of Environmental Chemical Engineering 7, 103257. https://doi.org/10.1016/j.jece.2019.103257
Harwanto, D., Oh, S.-Y. and Jo, J.-Y. (2011). Comparison of the nitrification efficiencies of three biofilter media in a freshwater system. Fisheries and Aquatic Sciences 14, 363-369. https://doi.org/10.5657/fas.2011.0363
Michaud, L., Blancheton, J.P., Bruni, V. and Piedrahita, R. (2006). Effect of particulate organic carbon on heterotrophic bacterial populations and nitrification efficiency in biological filters. Aquacultural Engineering 34, 224-233. https://doi.org/10.1016/j.aquaeng.2005.07.005
Michaud, L., Lo Giudice, A., Interdonato, F., Triplet, S., Ying, L. and Blancheton, J.P. (2014). C/N ratio-induced structural shift of bacterial communities inside lab-scale aquaculture biofilters. Aquacultural Engineering 58, 77-87. https://doi.org/10.1016/j.aquaeng.2013.11.002
Mnyoro, M.S., Munubi, R.N., Pedersen, L.-F. and Chenyambuga, S.W. (2022). Evaluation of biofilter performance with alternative local biomedia in pilot scale recirculating aquaculture systems. Journal of Cleaner Production 366, 132929. https://doi.org/10.1016/j.jclepro.2022.132929
Rusten, B., Eikebrokk, B., Ulgenes, Y. and Lygren, E. (2006). Design and operations of the Kaldnes moving bed biofilm reactors. Aquacultural Engineering 34, 322-331. https://doi.org/10.1016/j.aquaeng.2005.04.002
Summerfelt, S.T. (2006). Design and management of conventional fluidized-sand biofilters. Aquacultural Engineering 34, 275-302. https://doi.org/10.1016/j.aquaeng.2005.08.010
Summerfelt, S.T., Zühlke, A., Kolarevic, J., Reiten, B.K.M., Selset, R., Gutierrez, X. and Terjesen, B.F. (2015). Effects of alkalinity on ammonia removal, carbon dioxide stripping, and system pH in semi-commercial scale water recirculating aquaculture systems operated with moving bed bioreactors. Aquacultural Engineering 65, 46-54. https://doi.org/10.1016/j.aquaeng.2014.11.002